Drivers Scanpal 2 Metrological
The software suit for this device can be downloaded from This device uses the data_read.exe program to download the data from the data collector. To set this up create a directory such as c: metro Copy the data_read.exe program from the metrologic install directory into this directory. Use the data_read.exe program to test your communication with the data collector, when you have the setting correct, make note of them. In System Five, setupwizard, Point of Sale Devices, data collector/file import settings, Set the Data Collector File Format to Item,quan Set Data Collector Program Interface to Use Command line parameters Command Line c: metro data_read.exe Parameters data.txt,,,1,1,1,1,1,0,0,2 *Replace with parameters from the list below.
Jun 21, 2012. Most USB-HID (set preamble of control B) (medium). Most scanners with OPOS driver support. ☻Tested Product: Barcode Scanner w/ USB Kit. MFG: Metrologic. Model: ScanPal®2. Ease of Configuration: medium 3). Mar 26, 2013 - 34 sec - Uploaded by GETFEET SDN BHDmobile computer ScanPal 5100 Mobile Computer Honeywell's ScanPal 5100 is a.
Drumagog 4 Platinum Keygen Free on this page. The following steps are used to configure the MK5502 Data Collector: 1. Install the OptimusS Software that came with the Data Collector. The Path is Start >Programs >Optimus Software >Optimizer. The Data Collector requires you to download a program, which allows it to recognize serial numbers. First we will setup the hardware aspect of the Data Collector.
Plug one end of the USB Serial Cable to the host computer, and the other end to the RS 232 port on the back of the Cradle. As well, plug in the power cord to the right of the RS 232 port, and the other end to an available outlet. Now you can place the Data Collector into the Cradle and it should be able to charge. Hold down the power button on the bottom right corner of the device, and the device should power on. At this point, if you try scanning an item, you will get a “Wrong data type” Error. This is due because there is NO program downloaded to the scanner that makes it recognize serialized items. So the next step will see you downloading a program to the Data Collector.
To download the default Optimus program, navigate to the Optimus Program which is located at (Start >Programs >Optimus Software.) 5. Once the software has loaded, click on File on the top Menu, and select Open.
The location of the default Optizmier program (opt file) is: C: Program Files Metrologic Instruments Optimus Software Sample Optimizer Applications Batch Examples OptimusS. Open the file named Optimus Default Example.opt 7. Now turn on the Data Collector, and press the ESC button on the left side.
On the menu, select the Utilities option and press the Left arrow to enter. The next step is to select “ Transfer Files” and then “ Get Program”. Verify that the method of connection is through the “ Cradle” and that the baud rate is 115200.
License Code For Verbace Pro: Software Free Download. Once that is done, go back to the software, click Tools on the top menu, and navigate to Communication >Download Program. The program you opened previously which was the default file will now be downloaded through the cradle to the data collector. Once the program has downloaded to the data collector, press the up arrow on the collector, and select “ Run Program.
This will execute the default program which was just downloaded. You should now be able to Scan an Item, and input the Quantity of the item after the initial scan. System 5 Configuration.
To Setup the Metrologic MK5502 Data Collector in System 5 complete the following: 1. Start System 5 and navigate to “Setup Tools >Setup Wizard >Advanced Mode >Point of Sale Devices >Data Collector” 2.
Under “Data Collector File Format” Select “Item,quan” and under the “Data collector program interface” section select “Command line Parameters”. For “Command Line” specify the location of the Optimus program. Type in: “C: Program Files Metrologic Instruments Optimus Software Optimizer.exe”. For the “Parameters” field type the file you are uploading the data to and as well the COM Port you are using in accordance with the Data Collector. The format will be similar to this: “file.TXT,4,1,1,1,1,1,1,0”.
For the “Result File Name” field specify the location of the file that is receiving the data from the data collector. For example, if the file was called test123.txt and located in the root of the cd drive it would look like this: “C: test123.txt” Unitech.